In electrical engineering, isolatedphase bus ipb, also known as phaseisolated bus pib in. Around the world, azzs isolated phase bus duct systems are found in a wide range of critical applications that demand the highest degree of reliability. One of our most popular units for vacuum interrupters within switchgear or reclosers is the pft503cmf, a 50 kv at 3 kva 1piece ac hipot with an integrated output cable. Electrical distribution system bus duct manufacturer. Isolated phase bus duct is an electronic contraption that passes on tremendous streams amongst a generator and its transformer in a power or enormous hydroelectric power plant. Mdy busduct system a reliable and safe solution for power transmission 5 mdy technical data rated voltage u e. Segregatedphase bus one in which all phase conductors are in a common metal enclosure but are segregated by metal barriers between phases. Experts on isolated phase and nonsegregated bus systems at rms energy, our team is considered expert on repairs, maintenance and installations of isolated phase and nonsegregated bus duct systems. Innovative isolated phase bus duct systems to meet global demands.
Ebi abstract the purpose of this presentation is to educate the audience on best practices that have been identified for analysis, inspection, cleaning, and maintenance of the bus duct systems of the. The isolated phase bus is made of highgrade aluminum for the isolated phase bus enclosure and the isolated phase bus. It is an alternative means of conducting electricity to power cables or cable bus originally a busway consisted of bare copper conductors supported on inorganic insulators, such as porcelain. Isolated phase bus ducts ipb isolated phase busducts ipb with air insulation this type of duct is used primarily for the outlet of generator outputs at current levels as high as 28 ka and voltages of 36 kv.
Isolated phase bus ipb is the solution for main generator leads with current ratings from 3ka up to 50 ka. Nonsegregated phase bus a wide range of fittings duct is an assembly of bus conductors with associated connections, joints and insulating supports confined within a metal enclosure without inter phase barriers. This type of enclosure is dealt separately in chapter 31. From the bid documents, specifications, andor factory drawings, the. The basic principle of the busducts arrangement enables magnetic field.
Isolated phase bus has the conductor for each phase in a separate metal enclosure. Around the world, azzs medium voltage bus duct systems are found in a wide range of critical applications that demand the highest degree of reliability. This standard is to to ensure bus quality in process of packing, storing and shipping. Isolated phase bus industrial pdf catalogs brochure catalogs. Isolated phase bus duct suppliers powergear limited powergear is the manufacturer, supplier and exporter of power systems in india. Isolated phase busduct is a custom designed busbar system enclosed in an aluminium duct forming the interconnection between generator and generator transformer through generator circuit breaker. Specifically designed for power plant and large switching station applications, the stace bus duct miniflux allwelded isolated phase bus provides reliable operation with a minimum of maintenance. With a focus on innovation and customer dedication, our metal enclosed bus bar systems are custom. Isolated phase bus systems from technibus are used exclusively for main generator leads where minimal external electromagnetic fields and maximum phase to phase fault protection is required. Isolated phase bus is available for voltages ranging from 15kv through 38kv, with ampere ratings up through 42,000 amps. Isolated phase bus duct qlfm isolated phase busduct is specially designed for major circuit connections between 50mwmw generator outgoing.
Im no expert, but id look at all of the joints in the bus enclosure. Ebi the nations premier specialty electrical and welding contractor specializing in bus duct services and solutions for related components. Long term storage is any amount of time over thirty 30 days after receipt of material or sixty 60 days after shipment from the factory. Because of its compact dimensions, relative light weight and userfriendly design, nonsegregated phase bus duct is easy to install.
These iso phase bus duct systems are the only critical components within the plant that have no redundancy and no quick replacement solutions. Azz isolated phase bus systems are found in a wide range of environments around the world. Nema defines a busway as a prefabricated electrical distribution system consisting of bus bars in a protective enclosure, including straight lengths, fittings, devices and accessories. Our programs ensure continuous improvement of our design and construction services, quality in our work safe execution and customer satisfaction. First, the center conductor, if copper, requires four to five times the amount of hardware than an aluminum extruded conductor. Isolated phase singlepole high current busducts are built. Service approaches to maintenance of isolated phase bus duct ipbd systems are not maintenancefree. In electric power distribution, a bus duct also called busway, is a sheet metal duct containing either copper or aluminium busbars for the purpose of conducting a substantial current of electricity. Nonsegregated phase bus has all phase conductors in a common enclosure with an air space between phases. Fully rated, isolated and insulated neutral conductor can be provided. The main bus and its enclosure is normally in a tubular form, in view of the inherent advantages of a tubular figure 31. Isolated phase bus ducts systems are vital components in power plants that are often overlooked.
Our products are busducts, control panels, switchgear and much more. Unless mounted in its preferred position for maximum bus bar cooling, ventilated. Isolated phase bus maintenance inspections national. This includes power generation, petrochemical, industrial, medical, military, water technologies, and many others. For decades, plants and facilities have counted on azzs knowledge and expertise in customdesigned solutions to deliver unmatched. Saves time, cost and space spectra series busway is at least 50% lighter than comparable wire and conduit and lighter than competitors busway, too. These are delivered for power plants and immense trading station applications to give them veritable and security operation. The specification standard covers isolated phase bus duct and accessories for long term storage of the bus system. Pdf electromagnetic field and impedances of high current. Our design can be used for ac and dc excitation leads in power plants or in industrial applications where severe conditions can cause problems to the electrical environment. Power factoraverage phase linetoline voltage drop in volts per.
The number of phase bars is determined by the rated current and service conditions. Often, plant managers will make an incorrect assumption that ipb systems are selfmaintained with little human intervention needed. What links here related changes upload file special pages permanent link. Isolated phase bus in order to meet various requirements for power plant, hyosung designs. Whatever your isolated phase bus service needs are, our complete compliment of specialty trained inhouse isolated phase bus duct service teams, along with our state of the art equipment and tools, ensure we deliver a safe and high quality job from concept to completion. Installation of delta unibus isolated phase bus duct system.
Welcome to technibus as a global leader in isolated phase, nonsegregated and segregated bus products, technibus supplies systems for a wide range of applications and markets. Originally developed in the 1960s, isolated phase bus ipb or ipbd, is a method of construction for circuits carrying very large currents, typically between a generator and what is called a gsu generator stepup transformer. The ipb, a high current connection between generators and step up transformers, is a key component to transfer electricity to the power grid and also for unit. In addition, the mini phase bus duct is a very competitive product where multiple cables per phase. Isolatedphase bus one in which each phase conductor is enclosed by an individual metal housing separated from the adjacent conductor housing by an air space. Ipb isolated phase bus duct natural cooling and ipbfc isolated phase bus duct. Al 0 2500 2800 3500 4000 cu 1900 3200 3500 4300 4900 6000 width, mm 400 600 600 800 800 al 30 40 50 70 100 cu 55 80 105 125 150 180. Azz solutions continue to be the preferred option for medium and highvoltage bus ducts. Refurbishment of isolated phase bus that was damaged by others prior to installation. Isolated phase bus duct maintenance and inspections. The bus may be selfcooled or may be forcecooled by means of circulating a gas or liquid. Powerbus can also provide an isolated ground for electrical systems that require a clean.
Isolated phase bus duct ipbd bus duct system suppliers. Taps are taken to unit auxiliary transformer, lavt cubicle, excitation cubicle etc. This bus can be used in reduced space and is also designed for ac or dc excitation leads in power plants or for industrial applications where severe conditions can cause problems to the electrical equipment. Busduct is a sheet metal duct with aluminium or copper bus bars, and used as a reliable link for transferring power from one equipment to other at desired voltage levels. The isolated phase bus duct connects the output of the main generator to two other components. The stepup transformer increases the generator voltage from 22,000 volts or. The ir scan should pinpoint any hot spots in the enclosure, however, and make any joint resistance problem obvious. Welded on the side sus band rebber bellows angle bar see detail 1 channel detail 2 welded. The bus is designed for easy installation and meets all applicable safety standards. Miniphase isolated phase bus duct abb us electrification. Unit 1 and unit 2 isolated phase bus duct welding and installation.
The basic principle of the busducts arrangement enables magnetic field radiation to be reduced to below 5%. Improvements will be made to the neutral overvoltage. After world war ii, a new conductor alloy, 6101, was developed wbich had considerably higher yield strength and better creep resistance than 50. We pride ourselves on scoping every job as though its our own. Isophase bus condition assessment doble engineering. There are high circulating currents in the enclosure of iso phase bus duct. The mini phase bus duct is specifically designed for reduced space. Pdf recent progresses in busducts design researchgate. They can handle all of the following tasks in your. Foreign material or objects inside bus defective bus pt connections open pt highvoltage fuses contaminated insulators dirt, dust or water an electromagnetic interference emi diagnostics survey from doble is an online, noninvasive test that can detect a wide variety of defects in isolated phase bus duct.
1093 656 1360 437 928 1393 913 892 791 1516 786 630 1237 1431 576 1467 1170 569 861 1348 385 734 580 1483 273 562 834 123 1276 170 353 356 782 600 1437 1541 1582 788 273 713 298 1074 1202 1000 384 1016 584 355 1056